Globe Product Catalog_2018-19
Technical Information
CLEANING LABORATORY PLASTICWARE Most laboratory plasticware is easily cleaned in warm water with a mild detergent and soft cloth or sponge. Avoid using abrasive cleaners or scouring pads which can result in surfaces becoming scratched. Slight contamination can be removed using a chemically neutral (pH7) cleaning agent. Heavy contamination can be removed using an alkaline (pH up to 12) cleaning agent. If using an automatic laboratory dishwasher to wash plastic volumetric ware, such as measuring cylinders, employ a wash temperature below 60ºC. High temperatures can affect volumetric accuracy. Ultrasonic baths may be used for cleaning plasticware. However do take care that the products do not directly touch the transducer membrane.
RESIN CHARACTERISTICS Material
Brittleness
Max. Use
Melting Point
Specific
Temp. -100°C -100°C -100°C
Temp.
Range
Transparency Gravity Flexibility Microwaveable
HDPE High Density Polyethylene LDPE Low Density Polyethylene
120°C 125 to 138°C Translucent
0.95 0.92 1.20 1.19
Rigid
No
80°C
85 to 125°C Translucent
Excellent
Yes
PC
Polycarbonate
135°C
Transparent
Rigid Rigid Rigid Rigid Rigid
Marginal
PMMA Polymethylmethacrylate PMP Polymethylpentene
-20°C
85°C
85 to 105°C Transparent
No
0°C 0°C
120°C
235°C
Transparent
0.835
Yes Yes
PP PS
Polypropylene
135°C 160 to 176°C Translucent
0.9
Polystyrene
+20°C
90°C
Transparent
1.05
No
STERILIZATION CHART Material
Withstands Autoclaving
Sterilization Method
EtO Gas
Dry Heat
Radiation
Disinfectants
HDPE High Density Polyethylene LDPE Low Density Polyethylene
No No
Yes Yes Yes Yes Yes Yes No
No No No No
Yes Yes Yes Yes
Yes Yes
PC
Polycarbonate
Yes
Some Some
PMMA Polymethylmethacrylate PMP Polymethylpentene
No
Yes Yes
Yes
No No
Yes Yes
PP PS
Polypropylene
No No
Polystyrene Some Note: Observe the tolerated temperature ranges of plastic when autoclaving laboratory plasticware. Remove any stoppers, fittings or caps from the plasticware prior to autoclaving. Plastic vessels should be autoclaved separately from their closures and other fittings. Autoclaving vessels with their closures in place can lead to deformation and destruction of the vessels. All statements are advisory only and imply no liability on the part of Globe Scientific. All statements relating to the resistances of laboratory plasticware to high temperatures, chemicals and sterilization are based on statements from raw material manufacturers. No Yes
FOOD GRADE PRODUCTS Products indicated with the food grade symbol comply with the following regulations regarding food contact:
TEMPERATURE RESISTANCE CHART Material
F O O D GRADE
Temperature Resistance Low High
HDPE LDPE
High Density Polyethylene Low Density Polyethylene
-40ºC -50ºC -40ºC -40ºC -40ºC
+120ºC
+90ºC +90ºC +90ºC
• National and European Directive CE 1935/2004, Food contact suitable • EU Directive 2002/72, relating to plastic materials and articles intended to come into contact with food. • US FDA CFR 170/199, food contact suitable • US FDA CFR 177.1520, olefin polymers • US FDA CFR 177.1550, PTFE food contact suitable
PE
Polyethylene
PMMA Polymethylmethacrylate
POM Polyoxymethylene
+110ºC +130ºC
PP PS
Polypropylene
0ºC*
Polystyrene
-10ºC -20ºC
+70ºC
PVC +80ºC *Note: There are special blends of PP that are used in products like our CryoClear ™ cryogenic vials that are able to withstand temperatures down to -196ºC. Polyvinylchloride
www.globescientific.com
179
Made with FlippingBook flipbook maker